hpacucli controller slot = 1 ld 1 แสดงรายละเอียด
Smart Array P400 in Slot 1
array A
Logical Drive: 1
Size: 273.3 GB
Fault Tolerance: RAID 1+0
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Stripe Size: 128 KB
Status: OK
Array Accelerator: Enabled
Unique Identifier: xxxx
Disk Name: /dev/cciss/c0d0
Mount Points: /boot 196 MB, / 7.8 GB
Logical Drive Label: xxxxx
Mirror Group 0:
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 72 GB, Predictive Failure)
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 72 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 72 GB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 72 GB, OK)
Mirror Group 1:
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 72 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 72 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, OK)
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 72 GB, OK)
hpacucli controller slot = 1 รายการ
Smart Array P400 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: xxxx
Cache Serial Number: xxxx
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Chassis Slot:
Hardware Revision: Rev D
Firmware Version: 4.06
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Accelerator Ratio: 100% Read / 0% Write
Drive Write Cache: Disabled
Total Cache Size: 256 MB
Battery Pack Count: 0
SATA NCQ Supported: True
การเรียกใช้คำสั่งนี้มีความปลอดภัยหรือไม่
hpacucli controller slot=1 array A remove drives=1:8
hpacucli controller slot=1 pd 1:8 modify led=on
ขอมือรีโมตเพื่อถอดไดรฟ์และเปลี่ยนใหม่ จากนั้นเรียกใช้:
hpacucli controller slot=1 array A add drives=1:8
สิ่งนี้จะได้รับอาร์เรย์เพื่อสร้างใหม่อย่างปลอดภัยหรือไม่